News

CIXI gear flow meter applied to two-component flow monitoring of epoxy resin curing agent

sales01@cxflowmeter.com

Epoxy resin curing agent two-component flow monitoring flow meter
 
1. Working condition analysis:
 
Medium: epoxy resin (3Mpt420), curing agent
Viscosity: 5000cps
Flow: 0.5cc/s 2:1 ratio
Temperature and pressure: normal temperature and normal pressure
Power source: gear metering pump
Detection method: instantaneous flow monitoring
Display: There is a PLC on site
 
Specific working conditions: The customer is used for the production of golf balls, and the bonding of stainless steel and carbon fiber plates inside the golf ball.
 

 
2. Industry analysis:
 
Why use a JSN gear flow meter?
 
It is impossible to accurately measure the adhesion of the golf ball without a flowmeter. The adhesion of plastic and stainless steel needs to be bonded with glue, that is,
epoxy resin. More or less epoxy resin may cause the adhesion to be weak. affect quality.
 
If you want to know the specific selection and quotation of epoxy resin and other high viscosity liquid flow meters, please contact winny:sales01@cxflowmeter.com









 